Visit CCMB's Official Website

Uday KiranC G GokulanSantosh Kumar KunchaDhiviya VedagiriBingi Thrilok ChanderAedula Vinaya SekharSuchitra DontamalaArakatla Lohith ReddyKarthik Bharadwaj TallapakaRakesh K Mishra .

Published: 20 August 2020

Abstract

Rigorous testing is the way forward to fight the coronavirus disease 2019 pandemic. Here we show that the currently used and most reliable reverse transcription-polymerase chain reaction-based severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) procedure can be further simplified to make it faster, safer, and economical by eliminating the RNA isolation step. The modified method is not only fast and convenient but also at par with the traditional method in terms of accuracy, and therefore can be used for mass screening. Our method takes about half the time and is cheaper by ∼40% compared to the currently used method. We also provide a variant of the new method that increases the efficiency of detection by ∼30% compared to the existing procedure. Taken together, we demonstrate a more effective and reliable method of SARS-CoV-2 detection.

Introduction

Efficient diagnosis of an infectious pandemic carries inherent challenges such as biosafety during sample handling, skilled manpower, time consumption for testing, sensitivity of the testing method, and significant economic burden, irrespective of the nations. The present severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) is no exception for this, where the most efficient/reliable screening method is reverse transcription–polymerase chain reaction (RT–PCR)-based detection of viral nucleic acid from the patient sample. Rapidly growing number of coronavirus disease 2019 (COVID-19) cases warrant reliable and quicker testing methods. In the absence of specific drug and/or vaccine, the only way to control SARS-CoV-2 spread is large-scale screening and isolation of the infected individuals at early stages of infection. Screening using antibody-based methods is rapid but cannot be used for early-stage detection. Despite being a superior method, RT-PCR demands significant amount of time due to a laborious and expensive RNA isolation step from the viral transport medium (VTM) containing the swab samples. Currently, the challenge is to adapt a detection method which is quicker and still retaining the sensitivity of the standard RT-PCR-based method. Different studies have previously reported inexpensive, nucleic-acid extraction-free methods for PCR-based clinical diagnosis.

Here we show that the need for VTM as well as RNA isolation step for performing RT-PCR can be completely eliminated by extracting biological samples from dry swabs using Tris EDTA (TE) buffer, which is cost-effective and can be used as a quick screening procedure. In addition, we also show that the sensitivity of the entire RT-PCR based detection is enhanced by ∼30%, when using RNA isolated from TE buffer extract compared to the traditional method.

Materials and methods

Sample collection and transport

The swab samples were collected from voluntary patients at Gandhi Medical College & Hospital, Secunderabad, India. Two nasopharyngeal swabs were collected from each patient and one was transported as dry swab and another in 1 ml VTM (HiMedia Labs, Mumbai), respectively, and the samples were kept at 4°C till further processing.

Sample processing

Complete sample processing was done in the Biosafety level-3 (BSL-3) facility of Council of Scientific and Industrial Research – Centre for Cellular and Molecular Biology (CSIR-CCMB) by following Standard Operating Procedures.

  • Resuspension/extraction of biological material from dry swabs The dry swabs were transferred to 1.5 ml microfuge tubes containing 400 μl of TE buffer (10 mM Tris pH-7.4, 0.1 mM EDTA 0.1 mM). The swabs were cut to make them fit into the tubes and incubated at room temperature for 30 min to ensure the release of biological material.
  • Heat Inactivation For direct VTM to RT-PCR, an aliquot of 1 ml VTM samples was diluted three times before processing (as the existing recommendation suggests using 3 ml VTM for sample collection). An aliquot of 50 µl of the VTM (for direct VTM to RT-PCR) and TE extract was aliquoted from the respective vials containing swabs in to separate vials and heated at 98°C for 6 min on a dry heat block. The inactivated samples were directly used as a template for RT-PCR.

RNA isolation

The RNA isolation from 3 ml VTM and TE-buffer (containing dry swab) was performed using the QIAamp Viral RNA isolation kit (Qiagen, Germany) according the manufacturer’s protocol. In both cases, 150 μl of the sample was processed for RNA isolation.

RT-PCR

All the RT-PCR work was carried out in a BSL-2 facility of CSIR-CCMB, Hyderabad, India.

Heat inactivated VTM (direct VTM), TE buffer extract, and RNA isolated from TE buffer extract (TE-RNA) and VTM (VTM-RNA) from appropriate samples were tested using the Food and Drug Administration (FDA) approved LabGun COVID-19 detection RT-PCR kit (LabGenomics Co., Ltd., Republic of Korea). The primer–probe mix targets Envelope (E) gene (Cy5-labeled) and RNA-dependent RNA polymerase (RdRP; FAM-labeled) in the viral genome. The RT-PCR was performed according to the manufacturer protocol. The reactions were multiplexed after performing an in-house standardization (Supplementary dataTable S5). RT–PCR was performed in duplicates using LightCycler® 480 II (Roche Life Science, Germany) and the average values of two technical replicates were used for the analysis. For plotting purposes mean CT or dCT values of E or RdRP genes from both the replicates were used (Fig. 2 and Supplementary dataFig. S2). RNase P primers (Forward-5′-AGATTTGGACCTGCGAGCG-3′ and Reverse 5′-GAGCGGCTGTCTCCACAAGT-3′) and RNaseP Probe (5′-FAM-TTCTGACCTGAAGGCTCTGCGCG-BHQ-3′) were synthesized by as per ICMR, India guidelines (https://www.icmr.gov.in/pdf/covid/labs/1_SOP_for_First_Line_Screening_Assay_for_2019_nCoV.pdf). RNaseP oligos were synthesized at Eurofins Scientific, India. RT-PCR with RNase P primer–probe mix was performed only once.

Microsoft Excel and Origin software were used to generate the plots; Microsoft PowerPoint was used to generate the images. Heatmaps were constructed using heatmapper.ca [7].

Ethical statement

The study follows the institutional ethics committee guidelines (IEC number: 82/2020).

Results and discussion

We first hypothesized that SARS-CoV-2 nucleic acid could be detected directly by using VTM containing swabs of COVID-19 patients. This methodology (direct VTM method) involves the lysis of the virions (in VTM) by heating a 50 µl aliquot of VTM at 98°C for 6 min, followed by using 4 µl of this as a template for subsequent RT–PCR reaction targeting. However, our results showed a 50% reduction in the detection efficiency of positive samples (n = 16) compared to the traditional RNA isolation-based method (Supplementary dataFig. S1A and B; Supplementary dataTable S1).

Although our data put forth the feasibility of using VTM instead of extracted RNA, the detection ability of this method is limited to samples with moderate to high viral load. Probable reasons for this decreased efficiency could be dilution of the samples in 3 ml VTM or presence of PCR inhibitors in VTM, and to overcome this limitation, we changed our sample collection strategy. To test the new strategy, two nasopharyngeal swab samples were collected from each of the 14 patients with one swab transported dry and another in VTM and processed further (refer Methods for detail; Fig. 1A). Of the 14 patients, five were tested negative and the remaining nine positive samples were used for comparison. The results revealed that the performance of dry swab-TE buffer extracts in direct RT–PCR and the currently used standard method of detection which has the additional RNA extraction step from VTM samples were comparable (Supplementary dataTable S2 D1–D14), wherein, both the methods yielded same result for 11 out of 14 samples (six positives and five negatives) while the result differed for three samples.

Read more at: https://academic.oup.com/biomethods/article/5/1/bpaa017/5894966